RESISTANCE TEST  RESISTANCE TEST  (1) Disconnect connector P113 from pressure  transducer connector.  (2) Set multimeter to ohms.  (3) Connect positive (+) probe of multimeter to  pressure transducer connector pin A.  (4) Connect negative (-) probe of multimeter to  pressure transducer connector pin B and  note reading on multimeter.  (5) If 1-50 ohms resistance is not present, replace  pressure transducer (para 12-7).  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  pressure transducer connector pin B.  (3) Connect negative (-) probe of multimeter to  pressure transducer connector pin C and  note reading on multimeter.  (4) If 1-50 ohms resistance is not present, replace  pressure transducer (para 12-7).  Change 2 2-958.5  TM 9-2320-366-20-2