TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 53 of 1632

RESISTANCE TEST RESISTANCE TEST TM 9-2320-366-20-2 Change 2 2-958.1 (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to pneumatic controller connector pin D. (3) Connect negative (-) probe of multimeter to pneumatic controller connector pin B and note reading on multimeter. (4) If 30-80 ohms resistance is not present, replace manifold valve assembly (para 12-7). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to pneumatic controller connector pin F. (3) Connect negative (-) probe of multimeter to pneumatic controller connector pin A and note reading on multimeter. (4) If 30-80 ohms resistance is not present, replace manifold valve assembly (para 12-7).