TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 53 of 1632
RESISTANCE TEST  RESISTANCE TEST  TM 9-2320-366-20-2  Change 2 2-958.1  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  pneumatic controller connector pin D.  (3) Connect negative (-) probe of multimeter to  pneumatic controller connector pin B and  note reading on multimeter.  (4) If 30-80 ohms resistance is not present,  replace manifold valve assembly  (para 12-7).  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  pneumatic controller connector pin F.  (3) Connect negative (-) probe of multimeter to  pneumatic controller connector pin A and  note reading on multimeter.  (4) If 30-80 ohms resistance is not present,  replace manifold valve assembly (para 12-7).