TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 514 of 1632

TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1390 2-1390 2-1390 2-1390 2-1390 YES 1. Other crane functions from remote station OK. NO START KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS WARNING Read WARNING on following page. Go to step 3 of this fault. Faulty swing CCW solenoid cable. Faulty swing CCW solenoid. Faulty SWING CW/CCW controller. Faulty remote control box internal wiring harness. Faulty external remote control cable. Faulty remote control cable. Is 24 vdc present at junction box assembly terminal board position 9? INITIAL SETUP Equipment Conditions Outriggers lowered (TM 9-2320-366-10-1). Crane erected with approximately five feet of cable payed out (TM 9-2320-366-10-1). Engine shut down (TM 9-2320-366-10-1). Personnel Required (2) Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) Multimeter, Digital (Item 22, Appendix C) STE/ICE-R (Item 41, Appendix C) References TM 9-4910-571-12&P Voltage Test or STE/ICE-R Test #89 REASON FOR QUESTION This question eliminates possible problems and determines where to continue troubleshooting. e129. M1089 MATERIAL HANDLING CRANE (MHC) SWING CCW DOES NOT OPERATE FROM REMOTE STATION