TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 514 of 1632
TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2  2-1390 2-1390 2-1390 2-1390 2-1390  YES  1.  Other crane functions from  remote station OK.  NO  START  KNOWN INFO  POSSIBLE PROBLEMS  TEST OPTIONS  WARNING  Read WARNING  on following page.  Go to step 3 of this fault.  Faulty swing CCW  solenoid cable.  Faulty swing CCW  solenoid.  Faulty SWING CW/CCW  controller.  Faulty remote control  box internal wiring  harness.  Faulty external remote  control cable.  Faulty remote control  cable.  Is 24 vdc present at  junction box assembly  terminal board position 9?  INITIAL SETUP  Equipment Conditions  Outriggers lowered (TM 9-2320-366-10-1).  Crane erected with approximately five feet  of cable payed out (TM 9-2320-366-10-1).  Engine shut down (TM 9-2320-366-10-1).  Personnel Required  (2)  Tools and Special Tools  Tool Kit, Genl Mech (Item 46, Appendix C)  Multimeter, Digital (Item 22, Appendix C)  STE/ICE-R (Item 41, Appendix C)  References  TM 9-4910-571-12&P  Voltage Test or  STE/ICE-R Test #89  REASON FOR QUESTION  This question eliminates  possible problems and  determines where to  continue troubleshooting.  e129. M1089 MATERIAL HANDLING CRANE (MHC) SWING CCW DOES NOT  OPERATE FROM REMOTE STATION