TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 51 of 1632

CONTINUITY TEST CONTINUITY TEST TM 9-2320-366-20-2 Change 2 2-957 (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P110 socket P. (3) Connect negative (-) probe of multimeter to terminal lug TL50 and note reading on multimeter. (4) If continuity is not present, replace CTIS cable assembly (para 7-60). (5) Connect connector P110 to CTIS ECU. (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P110 socket C. (3) Connect negative (-) probe of multimeter to connector P112 socket E and note reading on multimeter. (4) If continuity is not present, replace CTIS cable assembly (para 7-60).