TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 509 of 1632

TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1385 2-1385 2-1385 2-1385 2-1385 CONTINUITY TEST (1) Remove SWING CW/CCW controller (para 7-32). (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter on pin L of remote control box connector. (4) Connect negative (-) probe of multimeter on pin 4 of SWING CW/CCW controller internal wiring harness and note reading on multimeter. (5) Position remote control box switch to ON. (6) Connect positive (+) probe of multimeter on pin H of remote control box connector. (7) Connect negative (-) probe of multimeter on pin 1 of SWING CW/CCW controller internal wiring harness and note reading on multimeter. (8) If continuity is not present, replace remote control box internal wiring harness (para 7-32). (9) If continuity is present, replace SWING CW/CCW controller (para 7-32). (10) Position remote control box switch to OFF. (11) Install SWING CW/CCW controller (para 7-32). (12) Close cover on junction box. (13) Tighten four screws on junction box cover. (14) Stow crane (TM 9-2320-366-10-1).