TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1369 2-1369 2-1369 2-1369 2-1369 CONTINUITY TEST (1) Disconnect telescope out solenoid connector from telescope out solenoid. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter on pin 2 of telescope out solenoid cable connector. (4) Connect negative (-) probe of multimeter on ground and note reading on multimeter. (5) Connect positive (+) probe of multimeter on pin 1 of telescope out solenoid cable connector. (6) Connect negative (-) probe of multimeter on terminal board lower position 11 and note reading on multimeter. (7) If continuity is not present, replace telescope out solenoid cable (para 7-123). (8) If continuity is present, notify DS Maintenance. (9) Connect telescope out solenoid cable connector to telescope out solenoid. (10) Close cover on junction box. (11) Tighten four screws on junction box cover. (12) Stow crane (TM 9-2320-366-10-1).