TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 491 of 1632
TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2  2-1367 2-1367 2-1367 2-1367 2-1367  OUTPUT VOLTAGE TEST  (9) Position TELESCOPE IN/OUT controller to OUT  and note reading on multimeter.  (10) If 24 volts dc is not present, go to step 3 of  this fault.  NOTE  Step (9) requires the aid  of an assistant.  Remove rings, bracelets, watches, necklaces,  and any other jewelry beffore working around  vehicle. Jewelery can catch on equipment and  cause injury or short circuit across electrical  circuits and cause severe burns or electrical  shock.  WARNING  (1) Connect external remote control cable to  remote control box (TM 9-2320-366-10-1).  (2) Loosen four screws on junction box.  (3) Open cover on junction box.  (4) Position MAIN POWER switch to ON.  (5) Lift guard and position remote control box  ON/OFF switch to ON.  (6) Set multimeter to volts dc.  (7) Connect positive (+) probe of multimeter on  terminal board lower position 11.  (8) Connect negative (-) probe of multimeter on  ground quick-connect terminal board  (above MAIN POWER switch).