TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 47 of 1632

CONTINUITY TEST CONTINUITY TEST TM 9-2320-366-20-2 Change 2 2-953 (1) Remove kick panel (para 16-3). (2) Disconnect connector P112 from pneumatic controller connector. (3) Disconnect connector J111 from connector P111. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to connector P111 pin A. (6) Connect negative (-) probe of multimeter to connector P112 socket A and note reading on multimeter. (7) If continuity is not present, replace CTIS cable assembly (para 7-60). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P111 pin A. (3) Connect negative (-) probe of multimeter to connector P112 socket B and note reading on multimeter. (4) If continuity is not present, replace CTIS cable assembly (para 7-60). (5) Connect connector J111 from connector P111.