TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1345 2-1345 2-1345 2-1345 2-1345 CONTINUITY TEST (1) Disconnect boom down solenoid connector from boom down solenoid. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter on pin 2 of boom down solenoid cable connector. (4) Connect negative (-) probe of multimeter on ground and note reading on multimeter. (5) Connect positive (+) probe of multimeter on pin 1 of boom down solenoid cable connector. (6) Connect negative (-) probe of multimeter on terminal board lower position 14 and note reading on multimeter. (7) If continuity is not present, replace boom down solenoid cable (para 7-106). (8) If continuity is present, notify DS Maintenance. (9) Connect boom down solenoid cable connector to boom down solenoid. (10) Close cover on junction box. (11) Tighten four screws on junction box cover. (12) Stow crane (TM 9-2320-366-10-1).