TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1333 2-1333 2-1333 2-1333 2-1333 CONTINUITY TEST (1) Disconnect boom up solenoid connector from boom up solenoid. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter on pin 2 of boom up solenoid cable connector. (4) Connect negative (-) probe of multimeter on ground and note reading on multimeter. (5) Connect positive (+) probe of multimeter on pin 1 of boom up solenoid cable connector. (6) Connect negative (-) probe of multimeter on terminal board lower position 13 and note reading on multimeter. (7) If continuity is not present, replace boom up solenoid cable (para 7-108). (8) If continuity is present, notify DS Maintenance. (9) Connect boom up solenoid cable connector to boom up solenoid. (10) Close cover on junction box. (11) Tighten four screws on junction box cover. (12) Stow crane (TM 9-2320-366-10-1).