TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1309 2-1309 2-1309 2-1309 2-1309 CONTINUITY TEST (1) Disconnect hoist up solenoid connector from hoist up solenoid. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter on pin 2 of hoist up solenoid cable connector. (4) Connect negative (-) probe of multimeter on ground and note reading on multimeter. (5) Connect positive (+) probe of multimeter on pin 1 of hoist up solenoid cable connector. (6) Connect negative (-) probe of multimeter on terminal board lower position 15 and note reading on multimeter. (7) If continuity is not present, replace hoist up solenoid cable (para 7-113). (8) If continuity is present, notify DS Maintenance. (9) Connect hoist up solenoid cable connector to hoist up solenoid. (10) Close cover on junction box. (11) Tighten four screws on junction box cover. (12) Stow crane (TM 9-2320-366-10-1).