TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1303 2-1303 2-1303 2-1303 2-1303 CONTINUITY TEST Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuit and cause severe burns or electrical shock. WARNING (1) Connect external remote control cable to left or right remote control cable bulkhead connector. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter on pin E of remote control cable connector. (4) Connect negative (-) probe of multimeter on pin B of remote control cable connector and note reading on multimeter. (5) If 24 vdc is not present, replace external remote control cable. (6) Disconnect external remote control cable from left or right remote control cable bulkhead connector. (7) Install cover on left or right remote control cable bulkhead connector.