TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 424 of 1632

TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1300 2-1300 2-1300 2-1300 2-1300 NO YES START KNOWN INFO TEST OPTIONS REASON FOR QUESTION Battery voltage OK. Overload shutdown system OK. Hydraulic system shutdown relay OK. Faulty remote control cable. Faulty external remote control cable. Faulty remote control box ON/OFF switch. Faulty remote control box internal wiring. Voltage Test or STE/ICE Test #89 If 24 vdc is not present, remote control cable is faulty. WARNING Read WARNING on following page. Is 24 vdc present at remote control bulkhead connector pin E? 1. POSSIBLE PROBLEMS INITIAL SETUP Equipment Condition Engine shut down (TM 9-2320-366-10-1). Personnel Required (2) Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) STE/ICE-R (Item 41, Appendix C) Multimeter, Digital (Item 22, Appendix C) References TM 9-4910-571-12&P e121. M1089 MATERIAL HANDLING CRANE (MHC) DOES NOT OPERATE FROM REMOTE CONTROL Replace remote control cable (para 7-115 or 7-118).