TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 416 of 1632

TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1292 2-1292 2-1292 2-1292 2-1292 YES START 1. NO WARNING Read WARNING on following page. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS Battery voltage OK. Circuit breakers OK. Power control cable assembly OK. Auxiliary panel cable assembly OK. Dashboard cable assembly OK. Hydraulic system OK. Faulty crane power cable. Faulty junction box assembly. Is 24 vdc present at junction box assembly terminal board position 2? INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-366-10-1). Personnel Required (2) Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) Multimeter, Digital (Item 22, Appendix C) STE/ICE-R (Item 41, Appendix C) References TM 9-491-571-12&P Voltage Test or STE/ICE-R Test #89 REASON FOR QUESTION If 24 vdc is not present, crane power cable is faulty. e120. M1089 MATERIAL HANDLING CRANE (MHC) DOES NOT OPERATE Replace crane power cable (para 7-79).