TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1275 2-1275 2-1275 2-1275 2-1275 CONTINUITY TEST (1) Loosen four screws on junction box. (2) Open cover on junction box. (3) Visually inspect the wiring around terminal board position 28 for shorted wires that could put 24 vdc on position 28. (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to terminal board position 28. (3) Connect negative (-) probe of multimeter to terminal board position 6 and note reading on multimeter. (4) If continuity is not present, replace overload lockout cable (para 7-27). (5) If continuity is present, notify DS Maintenance. (6) Close cover on junction box. (7) Tighten four screws on junction box. (8) Connect batteries (para 7-57).