TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 397 of 1632
TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1273 2-1273 2-1273 2-1273 2-1273 CONTINUITY TEST CONTINUITY TEST (1) Loosen four screws on junction box. (2) Open cover on junction box. (3) Disconnect overload lockout cable connector from overload shutdown box. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter in socket A of overload lockout cable connector. (6) Connect negative (-) probe of multimeter to terminal board position 6 and note reading on multimeter. (7) If continuity is not present, replace overload lockout cable (para 7-95). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter in socket B of overload lockout cable connector. (3) Connect negative (-) probe of multimeter on terminal board position 28 and note reading on multimeter. (4) If continuity is not present, replace overload lockout cable (para 7-95). (5) If continuity is present, perform Electrical System Troubleshooting (e116. M1084/M1086 Hoist Up Lockout Does Not Activate, e117. M1084/M1086 Boom Down Lockout Does Not Activate, e118. M1084/M1086 Boom Up Lockout Does Not Activate, and e119. M1084/M1086 Telescope Out Lockout Does Not Activate). (6) Connect overload lockout cable connector to overload shutdown box. (7) Close cover on junction box. (8) Tighten four screws on junction box. (9) Connect batteries (para 7-57).