TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 390 of 1632

TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1266 2-1266 2-1266 2-1266 2-1266 KNOWN INFO TEST OPTIONS Continuity Test or STE/ICE Test #91 REASON FOR QUESTION 4. POSSIBLE PROBLEMS Faulty remote control box internal wiring harness. Faulty SWING CW/CCW controller. If continuity is not present, remote control box internal wiring harness is faulty. If continuity is present, SWING CW/CCW controller is faulty. Other crane functions from remote station OK. Swing CCW solenoid cable OK. Swing CCW solenoid OK. External remote control cable OK. Remote control cable OK. YES Is continuity present from remote control box connector pin A to SWING CW/CCW controller internal wiring harness pin 3 and from remote control box connector pin H to SWING CW/CCW controller internal wiring harness pin 1? NO Repair remote control box internal wiring harness (para 7-32). Replace SWING CW/CCW controller (para 7-32). e113. M1084/M1086 MATERIAL HANDLING CRANE (MHC) SWING CCW DOES NOT OPERATE FROM RE- e113. M1084/M1086 MATERIAL HANDLING CRANE (MHC) SWING CCW DOES NOT OPERATE FROM RE- e113. M1084/M1086 MATERIAL HANDLING CRANE (MHC) SWING CCW DOES NOT OPERATE FROM RE- e113. M1084/M1086 MATERIAL HANDLING CRANE (MHC) SWING CCW DOES NOT OPERATE FROM RE- e113. M1084/M1086 MATERIAL HANDLING CRANE (MHC) SWING CCW DOES NOT OPERATE FROM RE- MOTE STATION (CONT) MOTE STATION (CONT) MOTE STATION (CONT) MOTE STATION (CONT) MOTE STATION (CONT)