TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1263 2-1263 2-1263 2-1263 2-1263 CONTINUITY TEST (1) Disconnect swing CCW solenoid connector from swing CCW solenoid. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter on pin 2 of swing CCW solenoid cable connector. (4) Connect negative (-) probe of multimeter on ground and note reading on multimeter. (5) Connect positive (+) probe of multimeter on pin 1 of swing CCW solenoid cable connector. (6) Connect negative (-) probe of multimeter on terminal board lower position 17 and note reading on multimeter. (7) If continuity is not present, replace swing CCW solenoid cable (para 7-98). (8) If continuity is present, notify DS Maintenance. (9) Connect swing CCW solenoid cable connector to swing CCW solenoid. (10) Close cover on junction box. (11) Tighten four screws on junction box cover. (12) Stow crane (TM 9-2320-366-10-1).