TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 360 of 1632

TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1236 2-1236 2-1236 2-1236 2-1236 YES 1. Other crane functions from remote station OK. NO START KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS WARNING Read WARNING on following page. Go to step 3 of this fault. Is 24 vdc present at junction box assembly terminal board position 19? Faulty telescope out solenoid cable. Faulty telescope out solenoid. Faulty TELESCOPE IN/OUT controller. Faulty remote control box internal wiring harness. Faulty external remote control cable. Faulty remote control cable. INITIAL SETUP Equipment Conditions Outriggers lowered (TM 9-2320-366-10-1). Crane erected with approximately five feet of cable payed out (TM 9-2320-366-10-1). Engine shut down (TM 9-2320-366-10-1). Personnel Required (2) Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) Multimeter, Digital (Item 22, Appendix C) STE/ICE-R (Item 41, Appendix C) References TM 9-4910-571-12&P Voltage Test or STE/ICE-R Test #89 REASON FOR QUESTION This question eliminates possible problems and determines where to continue troubleshooting. e111. M1084/M1086 MATERIAL HANDLING CRANE (MHC) TELESCOPE OUT DOES NOT OPERATE FROM REMOTE STATION