TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2  2-1231 2-1231 2-1231 2-1231 2-1231  CONTINUITY TEST  (1) Remove TELESCOPE IN/OUT controller  (para 7-32).  (2) Set multimeter to ohms.  (3) Connect positive (+) probe of multimeter on pin  D of remote control box connector.  (4) Connect negative (-) probe of multimeter on pin  3 of TELESCOPE IN/OUT controller internal  wiring harness and note reading on  multimeter.  (5) Connect positive (+) probe of multimeter on pin  H of remote control box connector.  (6) Connect negative (-) probe of multimeter on pin  1 of TELESCOPE IN/OUT controller internal  wiring harness and note reading on  multimeter.  (7) If continuity is not present, replace remote  control box internal wiring harness (para 7-32).  (8) If continuity is present, replace TELESCOPE  IN/OUT controller (para 7-32).  (9) Install TELESCOPE IN/OUT controller  (para 7-32).  (10) Close cover on junction box.  (11) Tighten four screws on junction box cover.  (12) Stow crane (TM 9-2320-366-10-1).