TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1227 2-1227 2-1227 2-1227 2-1227 CONTINUITY TEST (1) Disconnect telescope in solenoid connector from telescope in solenoid. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter on pin 2 of telescope in solenoid cable connector. (4) Connect negative (-) probe of multimeter on ground and note reading on multimeter. (5) Connect positive (+) probe of multimeter on pin 1 of telescope in solenoid cable connector. (6) Connect negative (-) probe of multimeter on terminal board lower position 20 and note reading on multimeter. (7) If continuity is not present, replace telescope in solenoid cable (para 7-101). (8) If continuity is present, notify DS Maintenance. (9) Connect telescope in solenoid cable connector to telescope in solenoid. (10) Close cover on junction box. (11) Tighten four screws on junction box cover. (12) Stow crane (TM 9-2320-366-10-1).