TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 348 of 1632

TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1224 2-1224 2-1224 2-1224 2-1224 YES 1. Other crane functions from remote station OK. NO START KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS WARNING Read WARNING on following page. Go to step 3 of this fault. Faulty telescope in solenoid cable. Faulty telescope in solenoid. Faulty TELESCOPE IN/OUT controller. Faulty remote control box internal wiring harness. Faulty external remote control cable. Faulty remote control cable. Is 24 vdc present at junction box assembly terminal board position 20? INITIAL SETUP Equipment Conditions Outriggers lowered (TM 9-2320-366-10-1). Crane erected with approximately five feet of cable payed out (TM 9-2320-366-10-1). Engine shut down (TM 9-2320-366-10-1). Personnel Required (2) Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) Multimeter, Digital (Item 22, Appendix C) STE/ICE-R (Item 41, Appendix C) References TM 9-4910-571-12&P Voltage Test or STE/ICE-R Test #89 REASON FOR QUESTION This question eliminates possible problems and determines where to continue troubleshooting. e110. M1084/M1086 MATERIAL HANDLING CRANE (MHC) TELESCOPE IN DOES NOT OPERATE FROM REMOTE STATION