TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 300 of 1632

TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1176 2-1176 2-1176 2-1176 2-1176 YES 1. Other crane functions from remote station OK. NO START Is 24 vdc present at junction box assembly terminal board position 23? Faulty hoist up solenoid cable. Faulty hoist up solenoid. Faulty HOIST UP/DOWN controller. Faulty remote control box internal wiring harness. Faulty external remote control cable. Faulty remote control cable. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS WARNING Read WARNING on following page. Go to step 3 of this fault. INITIAL SETUP Equipment Conditions Outriggers lowered (TM 9-2320-366-10-1). Crane erected with approximately five feet of cable payed out (TM 9-2320-366-10-1). Engine shut down (TM 9-2320-366-10-1). Personnel Required (2) Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) Multimeter, Digital (Item 22, Appendix C) STE/ICE-R (Item 41, Appendix C) References TM 9-4910-571-12&P Voltage Test or STE/ICE-R Test #89 REASON FOR QUESTION This question eliminates possible problems and determines where to continue troubleshooting. e106. M1084/M1086 MATERIAL HANDLING CRANE (MHC) HOIST UP DOES NOT OPERATE FROM REMOTE STATION