TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 299 of 1632

TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1175 2-1175 2-1175 2-1175 2-1175 CONTINUITY TEST (1) Position ON/OFF switch to ON. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter on pin H of remote control box receptacle. (4) Connect negative (-) probe of multimeter on pin J of remote control box receptacle and note reading on multimeter. (5) If continuity is not present, replace ON/OFF switch (para 7-32). (6) Position ON/OFF switch to OFF. (7) Connect positive (+) probe of multimeter on pin E of remote control box recptacle. (8) Connect negative (-) probe of multimeter on pin K of remote control box receptacle and note reading on multimeter. (9) If continuity is not present, replace ON/OFF switch (para 7-32). (10) If continuity is present, notify DS Maintenance.