TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2  2-1137 2-1137 2-1137 2-1137 2-1137  CONTINUITY TEST  (1) Remove PDP cover (para 16-2).  (2) Remove three screws and washers from PDP.  (3) Remove three screws from PDP.  (4) Lift PDP outward to gain access.  (5) Disconnect terminal lugs TL158 and TL159  from start inhibit pushbutton switch.  (6) Set multimeter to ohms.  (7) Connect positive (+) probe of multimeter to  start inhibit pushbutton switch terminal 1.  (8) Connect negative (-) probe of multimeter to  start inhibit pushbutton switch terminal 2.  (9) Press start inhibit pushbutton switch and hold  (TM 9-2320-366-10-1) and note reading on  multimeter.  (10) If continuity is not present, replace start  inhibit pushbutton switch (para 7-19).  (11) Install PDP on dashboard with three screws.  (12) Install three washers and screws in PDP.