TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1087 2-1087 2-1087 2-1087 2-1087 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to WTEC III relay K34 terminal 30. (3) Connect negative (-) probe of multimeter to WTEC III relay K34 terminal 87a and note reading on multimeter. (4) If continuity is not present, replace WTEC III relay K34 (para 7-9). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to WTEC III relay K34 terminal 86. (3) Connect negative (-) probe of multimeter to WTEC III relay K34 terminal 85 and note reading on multimeter. (4) If continuity is not present, replace WTEC III relay K34 (para 7-9).