TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1077 2-1077 2-1077 2-1077 2-1077 CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector PX33-D1. (3) Connect negative (-) probe of multimeter to connector PX50-2 and note reading on multimeter. (4) If continuity is not present, repair wire 1697 (para 2-45) or replace WTEC II dashboard cable assembly (para 7-10). (5) Connect connector PX33 to WTEC II VIM. (6) Tighten screw in connector PX33. (7) Connect connector PX50 to differential lock solenoid connector.