TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 189 of 1632
TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2  2-1065 2-1065 2-1065 2-1065 2-1065  CONTINUITY TEST  CONTINUITY TEST  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  connector J7-1.  (3) Connect negative (-) probe of multimeter to  ground and note reading on multimeter.  (4) If continuity is not present, repair wire 1426  (para 2-45) or replace WTEC II dashboard  cable assembly (para 7-10).  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  connector J7-2.  (3) Connect negative (-) probe of multimeter to  ground and note reading on multimeter.  (4) If continuity is not present, repair wire 1408  (para 2-45) or replace WTEC II dashboard  cable assembly (para 7-10).