TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 171 of 1632
(10) Position dust boot on terminal lug TL35. CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to relay K11 socket 87A on PDP. (3) Raise cab (TM 9-2320-366-10-1). (4) Lift dust boot on terminal lug TL35. (5) Remove self-locking nut, washer, and terminal lug TL35 from voltage regulator. Discard self-locking nut. (6) Connect negative (-) probe of multimeter to terminal lug TL35 and note reading on multimeter. (7) If continuity is not present, go to step 9 of this fault. (8) Position terminal lug TL35 on voltage regulator with washer and self-locking nut. (9) Tighten self-locking nut to 23-27 lb-in. (3 N.m). Change 1 2-1056.1 TM 9-2320-366-20-2