TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 1244 of 1632
TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 TM 9-2320-366-20-2 2-1968 2-1968 2-1968 2-1968 2-1968 1. Check Temperature Air dryer purge valve may freeze open if temperature is below freezing and air dryer heater does not work. Is air temperature 32°F (O°C) or below? START YES NO KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION j3. AIR DRYER CONTINUALLY PURGES Does air dryer heater operate? 2. YES NO KNOWN INFO POSSIBLE PROBLEMS Check Heater Temperature Air may leak steadily from purge valve if purge valve is frozen and heater does not operate. TEST OPTIONS REASON FOR QUESTION INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-366-10-1). Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) Goggles, Industrial (Item 15, Appendix C) Faulty air dryer heater. Blocked air hose from air dryer to wet tank. Faulty air dryer. Faulty air compressor governor. Air hoses and fittings OK. Faulty air dryer heater. Blocked air hose from air dryer to wet tank. Faulty air dryer. Faulty air compressor governor. Air hoses and fittings OK. Go to step 3 of this fault. Perform Electrical Troubleshooting (e101. Air Dryer Does Not Operate (All Models Except M1090/M1094) or e102. M1090/M1094 Air Dryer Does Not Operate).