TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download

Page 1237 of 1632

SOAPY WATER LEAK TEST TM 9-2320-366-20-2 Change 1 2-1961 (1) Apply soapy water solution to hoses, fittings, and couplings. (2) Check hoses and fittings for bubbles, indicating leaks. (1) Open wet tank drain cock and check for excessive amounts of moisture. (2) If moisture exists in wet tank, service air dryer desiccant cartridge (para 23-11). (3) Close wet tank drain cock.