(1) Tighten air hose 107 at SYSTEM PARK air supply valve supply port. (2) Loosen air hose 103 at SYSTEM PARK air supply valve delivery port. (3) Check for presence of air from SYSTEM PARK air supply valve. (4) If no air is present, replace SYSTEM PARK air supply valve (para 11-20). Change 1 2-1883 TM 9-2320-366-20-2