TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 1093 of 1632
CAUTION  CONTINUITY TEST  NOTE  Inspect connector pins/sockets for damage,  corrosion, and serviceability. Check that  connector pins are not pushed back and  are capable of making good contact.  Use care when testing electrical connectors.  Do not damage connector pins or sockets  with multimeter probes. Failure to comply  may result in damage to equipment.  (1) Disconnect batteries (para 7-57).  (2) Remove PDP cover (para 16-2).  (3) Remove three screws from PDP.  (4) Remove three screws and washers from PDP.  (5) Lift PDP outward to gain access.  (6) Set multimeter to ohms.  (7) Connect positive (+) probe of multimeter to  connector P116 socket 4.  (8) Connect negative (-) probe of multimeter to  terminal board TB1 position 60 and note  reading on multimeter.  (9) If continuity is not present, Repair wire  146 from connector P116 socket 4  to terminal board TB1 position 60  (para 2-45) or replace WTEC III dashboard  cable assembly (para 7-11).  (10) Connect connector P116 to WTEC III ECU.  (11) Connect connector clamp to connector P116.  (12) Install kick panel (para 16-3).  TM 9-2320-366-20-2  Change 1 2-1822.25