TM-9-2320-366-20-2 MTV Unit Maintenance Manual M1083 Series - Volume 2 Download
Page 1089 of 1632
CAUTION  Use care when testing electrical connectors.  Do not damage connector pins or sockets  with multimeter probes. Failure to comply  may result in damage to equipment.  NOTE  Inspect connector pins/sockets for damage,  corrosion, and serviceability. Check that  connector pins are not pushed back and  are capable of making good contact.  CONTINUITY TEST  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  connector PX33 socket T.  (3) Connect negative (-) probe of multimeter to  ground and note reading on multimeter.  (4) If continuity is not present, Repair wire  186 from connector PX33 socket T to  terminal board TB2 position 15 (para 2-45)  or replace WTEC III dashboard cable  assembly (para 7-11).  TM 9-2320-366-20-2  Change 1 2-1822.21