CONTINUITY TEST  CONTINUITY TEST  (1) Disconnect connector P119 from connector  J119.  (2) Set multimeter to ohms.  (3) Connect positive (+) probe of multimeter to  connector P119R.  (4) Connect negative (-) probe of multimeter to  connector P73 pin C and note reading on  multimeter.  (5) Connect positive (+) probe of multimeter  to connector P119f.  (6) Connect negative (-) probe of multimeter to  connector P73 pin B and note reading on  multimeter.  (7) Connect positive (+) probe of multimeter  to connector P119Z.  (8) Connect negative (-) probe of multimeter to  connector P73 pin A and note reading on  multimeter.  (9) If continuity is not present on one or more  wires, notify DS Maintenance.  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  connector P119R.  (3) Connect negative (-) probe of multimeter to  all other pins in connector P119, one at a  time, and note reading on multimeter.  (4) If continuity is found between pin R and  any other pin, notify DS Maintenance.  (5) Perform steps (2) and (3) for P119f and  P119Z.  (6) If continuity is found between pin f and  any other pin, or between pin Z and any  other pin, notify DS Maintenance.  (7) Connect connector P73 to TPS connector.  Change 1 2-1771  TM 9-2320-366-20-2