TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 2-530 2-530 2-530 2-530 2-530 1. START Other indicator lights operate. Is continuity present through master stop indicator lamps? YES NO If continuity is not present, master stop indicator lamps are faulty. If continuity is present, lighted indicator display is faulty. Faulty master stop indicator lamps. Faulty lighted indicator display. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS Continuity Test or STE/ICE-R #91 REASON FOR QUESTION Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) STE/ICE-R (Item 41, Appendix C) Multimeter, Digital (Item 22, Appendix C) Wrench, Torque, 0-75 lb-in. (Item 90, Appendix B) References TM 9-4910-571-12&P e40. MASTER STOP INDICATOR DOES NOT OPERATE INITIAL SETUP Equipment Condition Engine shut down (TM 9-2320-366-10-1). Batteries disconnected (para 7-57). Personnel Required (2) Replace master stop indicator lamps (para 7-16). Replace lighted indicator display (para 7-16).