TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 2-497 2-497 2-497 2-497 2-497 WARNING Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuit and cause severe burns or electrical shock. VOLTAGE TEST (1) Disconnect connector J108 from connector P108. (2) Set multimeter to volts dc. (3) Connect positive (+) probe of multimeter to connector J108-18. (4) Connect negative (-) probe of multimeter to ground. (5) Position master power switch to on (TM 9-2320-366-10-1) and note reading on multimeter. (6) If 24 vdc is not present, repair wire 2034 (para 2-45) or replace auxiliary panel cable assembly (para 7-58). (7) If 24 vdc is present, repair wire 2034 (para 2-45) or replace M1090/M1094 dump power cable assembly (para 7-125). (8) Position master power switch to off (TM 9-2320-366-10-1). (9) Connect connector P108 to connector J108. (10) Connect connector P172 to connector J172. (11) Lower dump bed (TM 9-2320-366-10-1). (12) Install personnel heater (para 18-9).