TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 2-491 2-491 2-491 2-491 2-491 WARNING Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuit and cause severe burns or electrical shock. VOLTAGE TEST CONTINUITY TEST (1) Disconnect batteries (para 7-57). (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to connector P172-B. (4) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (5) If continuity is not present, repair wire 3022 (para 2-45) or replace M1090/M1094 dump power cable assembly (para 7-125). (6) If continuity is present, replace M1090/M1094 dump body switch (para 7-23). (7) Connect connector P172 to connector J172. (8) Lower dump bed (TM 9-2320-366-10-1). (9) Connect lighted indicator display to connector PX7. (10) Position lighted indicator display in instrument panel assembly with four screws. (11) Tighten four screws to 6-10 lb-in. (1 N·m). (12) Connect batteries (para 7-57). (1) Connect batteries (para 7-57). (2) Raise dump bed (TM 9-2320-366-10-1). (3) Disconnect connector P172 from connector J172. (4) Set multimeter to volts dc. (5) Connect positive (+) probe of multimeter to connector P172-B. (6) Connect negative (-) probe of multimeter to ground. (7) Position master power switch to on (TM 9-2320-366-10-1) and note reading on multimeter. (8) If 24 vdc is not present, go to step 5 of this fault. (9) Position master power switch to off (TM 9-2320-366-10-1).