TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download
Page 722 of 1824
TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 2-434 2-434 2-434 2-434 2-434 1. START YES Chemical alarm operates. This question eliminates possible problems and determines where troubleshooting continues. NO Faulty dashboard cable assembly. Faulty chemical detector indictor lamps. Faulty lighted indicator display. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS Continuity Test or STE/ICE-R #91 REASON FOR QUESTION Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) STE/ICE-R (Item 41, Appendix C) Multimeter, Digital (Item 22, Appendix C) Wrench, Torque, 0-75 lb-in. (Item 90, Appendix B) References TM 9-4910-571-12&P Is continuity present between lighted indicator display terminals 2 and 17? Go to step 3 of this fault. e26. CHEMICAL DETECTOR INDICATOR DOES NOT OPERATE INITIAL SETUP Equipment Condition Engine shut down (TM 9-2320-366-10-1). Batteries disconnected (para 7-57). Personnel Required (2)