TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download
Page 629 of 1824
TM 9-2320-366-20-1 CONTINUITY TEST NOTE Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. CAUTION Change 1 2-390.3 (1) Remove instrument panel assembly for access (para 7-15). (2) Disconnect connector clamp from FUEL gage connector. (3) Disconnect connector PX9 from FUEL gage connector. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to connector PX9 socket 1. (6) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (7) If continuity is not present, repair wire 3020 from connector PX9 socket 1 to connector PX4 socket 1 (para 2-45) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11).