TM 9-2320-366-20-1 CAUTION Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. CONTINUITY TEST Change 1 2-386.11 (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector PX12A socket 2. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If continuity is not present, repair wire 3020 from connector PX12A socket 2 to connector PX14A socket 2 (para 2-45) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (5) If continuity is present, repair wire 1908 from connector PX12A socket 1 to connector PX17A socket 1 (para 2-45) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (6) Connect connector PX12A to amber warning light switch lamp base connector. (7) Install instrument panel assembly (para 7-15).