TM 9-2320-366-20-1 Personnel Required (2) References TM 9-4910-571-12&P 1. REASON FOR QUESTION TEST OPTIONS KNOWN INFO INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-366-10-1). Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) STE/ICE-R (Item 41, Appendix C) Multimeter, Digital (Item 22, Appendix C) e16A. MASTER POWER SWITCH DOES NOT SHUT DOWN ENGINE Master power switch off. POSSIBLE PROBLEMS Faulty master power switch. Faulty relay K2. WARNING Read WARNING on following page. START Visual Inspection YES NO Replace master power switch (para 7-18). Replace relay K2 (para 7-09). 2-380.4 Change 2 Does engine shut down when circuit braker CB70 is removed from Power Distribution Panel (PDP)? If engine shuts down when circuit breaker CB70 is removed, master power switch is faulty. If engine does not shut down when circuit breaker CB70, relay K2 is faulty.