TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download
Page 556 of 1824
e13. VOLTS GAGE DOES NOT OPERATE OR IS INACCURATE INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-366-10-1). Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) STE/ICE-R (Item 41, Appendix C) Multimeter, Digital (Item 22, Appendix C) Personnel Required (2) References TM 9-4910-571-12&P NOTE Perform electrical troubleshooting e1. CIRCUIT BREAKER DOES NOT OPERATE on circuit breaker CB77 prior to beginning this task. START Is 24 VDC present on connector PX10 pin 3? WARNING CAUTION Read WARNING and CAUTION on following page. 1. Go to step 3 of this fault. NO YES TEST OPTIONS Voltage Test or STE/ICE-R Test #89 REASON FOR QUESTION This question eliminates possible problems and determines where troubleshooting continues. KNOWN INFO Circuit breaker CB77 OK. POSSIBLE PROBLEMS Faulty dashboard cable assembly. Faulty VOLTS gage. TM 9-2320-366-20-1 2-356 Change 1