TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download
Page 549 of 1824
TM 9-2320-366-20-1 Change 1 2-354.1 1 2 3 4 5 6 7 8 9 10 Switch Number Switch Setting Up Up Down Up Up Down Down Up Down Up (1) Remove two protective caps, self-locking nuts, retaining ring, and speedometer from instrument panel assembly. Discard self- locking nuts. (2) Note position of speedometer dip switches. Refer to Table 2-8.4. Speedometer Dip Switch Settings. (3) If speedometer dip switch setting(s) are incorrect, correct speedometer dip switch setting(s) (para 7-14). (4) If speedometer dip switch settings are correct, replace speedometer (para 7-14). (5) Position speedometer in instrument panel assembly with retaining ring and two self- locking nuts. (6) Tighten two self-locking nuts to 9 lb-in. (1 N·m). (7) Install two protective caps on speedometer. (8) Connect connector PX8 to speedometer connector. (9) Connect connector clamp on speedometer connector. (10) Install instrument panel assembly (para 7-10). Table 2-8.4. Speedometer Dip Switch Settings (11) Connect connector P111 to connector J111. (12) Install PDP on dashboard with three washers and screws. (13) Install three screws in PDP. (14) Install PDP cover (TM 9-2320-366-10-2).