TM 9-2320-366-20-1  RESISTANCE TEST  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  connector PX6 pin 4.  (3) Connect negative (-) probe of multimeter to  known good ground and note reading on  multimeter.  (4) If 202-243 ohms resistance is not  present, go to step 4 of this fault.  Change 2 2-338.1  (1) Start engine (TM 9-2320-366-10-1).  (2) Set multimeter to ohms.  (3) Connect positive (+) probe of multimeter to  connector PX6 pin 4.  (4) Connect negative (-) probe of multimeter to  known good ground and note reading on  multimeter.  (5) If 90-130 ohms resistance is not present,  replace engine oil pressure transmitter  (para 7-49).  (6) If 90-130 ohms resistance is present,  replace engine OIL PRESS gage (para 7-14).  (7) Shut down engine (TM 9-2320-366-10-1).  (8) Connect connector PX6 to engine OIL  PRESS gage connector.  (9) Connect connector clamp to engine OIL  PRESS gage connector.  (10) Install instrument panel assembly  (para 7-15).  RESISTANCE TEST