TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download

Page 499 of 1824

RESISTANCE TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector PX11 pin 4. (3) Connect negative (-) probe of multimeter to a known good ground and note reading on multimeter. (4) If less than 750 ohms is present, go to step 3 of this fault. (5) If greater than 750 ohms is present, replace WATER TEMP gage (para 7-14). Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back or not capable of making good contact. NOTE Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. CAUTION TM 9-2320-366-20-1 Change 1 2-326.1