TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download
Page 481 of 1824
CONTINUITY TEST  Use care when testing electrical connectors.  Do not damage connector pins or sockets  with multimeter probes. Failure to comply  may result in damage to equipment.  CAUTION  (10) Install instrument panel assembly (para  7-15).  (11) Connect batteries (para 7-57).  (1) Disconnect batteries (para 7-57).  (2) Remove instrument panel assembly for  access (para 7-15).  (3) Disconnect connector J31 from connector  P31.  (4) Set multimeter to ohms.  (5) Connect positive (+) probe of multimeter  to connector J31pin 5.  (6) Connect negative (-) probe of multimeter to  ground and note reading on multimeter.  (7) If continuity is not present, repair wire  3015 from connector J31 pin 5 to terminal  board TB2 position 18 on power  distribution panel (PDP) (para 2-45) or  replace WTEC II dashboard cable assembly  (para 7-10) or WTEC III dashboard cable  assembly (para 7-11).  (8) If continuity is present, repair wire 3015  from connector P31 socket 5 to terminal  lug TL29 (para 2-45) or replace engine  control cable assembly (para 7-80).  (9) Connect connector J31 to connector P31.  TM 9-2320-366-20-1  Change 1 2-315