TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download
Page 479 of 1824
CONTINUITY TEST WARNING VOLTAGE TEST Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuits and cause severe burns or electrical shock. (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to terminal lug TL29 on fuel solenoid. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If continuity is not present, go to step 4 of this fault. (5) If continuity is present, fuel solenoid is faulty, notify DS Maintenance. (6) Lower cab (TM 9-2320-366-10-1). TM 9-2320-366-20-1 Change 1 2-313 (1) Lower cab (TM 9-2320-366-10-1). (2) Remove power distribution panel (PDP) cover (para 16-2). (3) Remove relay K19 from power distribution panel (PDP). (4) Set multimeter to volts DC. (5) Connect positive (+) probe of multimeter to relay K19 socket 86 on power distribution panel (PDP). (6) Connect negative (-) probe of multimeter to ground (7) Position master power switch to on (TM 9-2320-366-10-1) and note reading on multimeter. (8) If 24 VDC is not present, go to step 5 of this fault. (9) If 24 VDC is present, replace start inhibit pushbutton switch (para 7-19). (10) Position master power switch to off (TM 9- 2320-366-10-1).