TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download

Page 463 of 1824

CONTINUITY TEST NOTE Tag terminal lugs and connection points prior to disconnecting. (1) Disconnect batteries (para 7-57). (2) Remove nut, lockwasher, washer, and terminal lugs TL37 and TL36 from left 24V BAT terminal stud on 200 AMP terminal block. Discard lockwasher. (3) Remove nut, lockwasher, washer, and terminal lugs TL1 and TL166 from right 24V BAT terminal stud on 200 AMP terminal block. Discard lockwasher. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to left 24V BAT terminal stud on 200 AMP terminal block. (6) Connect negative (-) probe of multimeter to right 24V BAT terminal stud on 200 AMP terminal block and note reading on multimeter. (7) If continuity is not present, replace 200 AMP terminal block (para 20-58). TM 9-2320-366-20-1 Change 1 2-284.15