KNOWN INFO TEST OPTIONS  REASON FOR QUESTION  11.  Service drive lights OK.  Circuit breaker CB70 OK.  Batteries OK.  POSSIBLE PROBLEMS  Faulty 100 AMP reverse polarity  relay.  Faulty 100 AMP reverse polarity  relay to power distribution  panel (PDP) 24 VDC cable.  Faulty battery to 100 AMP  reverse polarity relay 24 VDC  cable.  e4. 24 VDC CIRCUITS DO NOT OPERATE (CONT)  Continuity Test or  STE/ICE-R Test #91  Is continuity present from  terminal lug TL39 to  terminal lug TL37?  NO  YES  If continuity is not present,  battery to 100 AMP reverse  polarity relay 24 VDC cable is  faulty.  Replace battery to 100 AMP  reverse polarity relay 24 VDC  cable (para 7-75).  TM 9-2320-366-20-1  2-284.4 Change 1